We can't find the internet
Attempting to reconnect
Something went wrong!
Hang in there while we get back on track
Innovative liquid chromatography-mass spectrometry techniques for multiresidue analysis of emerging micropollutants in gammarus, an environmental sentinel species
AI summary Read the abstract
Researchers developed and validated advanced liquid chromatography-mass spectrometry (LC-MS/MS) methods to detect 42 emerging micropollutants—including PFAS, pharmaceuticals, and bisphenol A—in Gammarus fossarum, a freshwater crustacean used as a bioindicator. The methods, applied to caged shrimp in rivers under chemical stress, demonstrated improved sensitivity and selectivity for monitoring aquatic contamination at trace concentrations.
Notre mode de vie basée sur une société de consommation ou encore les activités industrielles contribuent au rejet de molécules potentiellement bioactives dans les eaux usées. En sortie de station d’épuration, certains de ces composés ne sont que partiellement éliminés, sont relargués dans les eaux de rejet et se retrouvent finalement dans l'environnement aquatique. Pour évaluer et surveiller la concentration de micropolluants dans les rivières, des espèces biotiques peuvent être utilisées comme indicateurs de l’état d’un écosystème. On peut citer notamment Gammarus fossarum ou gammare, une petite crevette qui se trouve naturellement dans les rivières et qui peut également être élevée en laboratoire puis placée dans des endroits spécifiques pour réaliser de la biosurveillance dite active. Les concentrations retrouvées dans les rivières sont de l’ordre du ng/g dans ces bioindicateurs, soit à l’état de traces. Il est donc nécessaire de disposer de méthodes analytiques permettant d’atteindre ces limites. La chromatographie liquide couplée à la spectrométrie de masse est une méthode très souvent utilisée pour l’analyse de contaminants émergents, mais elle comporte des limites en termes de sélectivité et sensibilité dans des matrices complexes telles que le biote. L’objectif de ce travail était d’étudier des méthodes basées sur l’utilisation de la micro-chromatographie liquide ou du mode de détection MRM3 en spectrométrie de masse pour pallier ces limitations. A partir d’une liste de 4 composés (18 perfluoroalkylés, 7 organoétains, 3 retardateurs de flamme, 19 produits pharmaceutiques et de soins personnels, et 3 pesticides), une méthode LC-MS/MS précédée d’une préparation d’échantillon de type QuEChERS a tout d’abord été développée, adaptée à la diversité physico-chimique des analytes. Un total de 40 composés a été validé, avec des limites de quantification comprises entre 0,04 ng/g et 230 ng/g. Ensuite la miniaturisation du système LC, avec un débit 20 fois plus faible qu’en LC conventionnelle, a permis l’ionisation de deux molécules supplémentaires, non-détectables avec la méthode précédente : le 4-tert-octylphénol et le bisphénol A. La méthode basée sur la microLC a donc finalement permis la validation de 42 molécules. Enfin, l’utilisation du mode MRM3 à la place du mode MRM lors du couplage avec la chromatographie a montré une augmentation de toutes les aires des composés recherchés, amenant une quantification plus précise. L’application de ces méthodes à des échantillons de gammares encagés dans des rivières soumises à différents types de pression chimique a montré leur intérêt pour la mise en évidence de la contamination en micropolluants.
More Papers Like This
A comprehensive review of emerging environmental contaminants of global concern
AI summary Read the abstract
This review comprehensively examined emerging contaminants including pharmaceuticals, PFAS, endocrine disruptors, and micro- and nano-plastics across environmental matrices, discussing their sources, environmental behavior, toxicological effects, and detection techniques. Advanced methods including LC-MS/MS, ELISA, PCR, and biosensors were highlighted as essential for identifying and quantifying these substances, with ECs implicated in endocrine disruption, antibiotic resistance, and bioaccumulation threatening food safety and public health.
Development of High-throughput Analytical Platforms Based on Chromatographic Techniques Coupled with Mass Spectrometry for the Identification And/or Quantification of Organic Micropollutants And/or Metabolites in Environmental, Food and Clinical Matrices
AI summary Read the abstract
This doctoral research developed high-throughput analytical methods using chromatography coupled with mass spectrometry to detect organic micropollutants including microplastics, pharmaceuticals, and PFAS in environmental, food, and clinical samples. Researchers optimized sustainable extraction and analysis protocols aligned with green analytical chemistry principles. The work advances the ability to monitor emerging contaminants and their transformation products across multiple types of sample matrices.
Development of an analytical method for the analysis of microplastics by Pyrolysis-GC/MS : application on Seine River sediments
AI summary Read the abstract
Researchers developed and validated an analytical method using pyrolysis coupled with gas chromatography-mass spectrometry (Py-GC/MS) for quantifying microplastics in complex environmental matrices, applying it to Seine River sediment samples rich in mineral and organic matter. They found that Py-GC/MS effectively determined mass concentrations of target polymers and proved complementary to micro-FTIR, though interfering compounds from organic-rich matrices required careful method optimization.
Screening of organic chemicals associated to virgin low-density polyethylene microplastic pellets exposed to the Mediterranean Sea environment by combining gas chromatography and liquid chromatography coupled to quadrupole-time-of-flight mass spectrometry
AI summary Read the abstract
Researchers screened organic chemicals that accumulate on virgin low-density polyethylene microplastic pellets exposed to the Mediterranean Sea over eight weeks. Using advanced mass spectrometry techniques, the study identified numerous sorbed contaminants, revealing how microplastics can act as carriers for pollutants in marine environments.
Développement d'une méthode de quantification des microplastiques par Pyr-GC-MS pour l'analyse de sédiments de la Seine
AI summary Read the abstract
Researchers developed and validated a pyrolysis-GC-MS method to quantify microplastics by polymer mass in sediments from the Seine River in France. The method complements spectroscopy-based particle-counting techniques, providing a more complete picture of microplastic contamination.
Research digests by email
When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.